Smart Room |
Smart Card Access control | |
|
Access Control
Energy Saving System
Hotel Room
Central Control
|
Functional
Description ·
Access
control:
Is secured using a smart cart reader outside the
controlled room. Up to 6 different user
groups may be inserted into the Smart
Room non-volatile memory
with entry rights. ·
Energy saving function: It
is secured using a smart card reader inside the room and also using a
magnetic switch to sense the opening of the window or balcony door of
the room.When
a valid smart card is inserted in the internal reader, a green led
shines to indicate the normal operation of the system. Then red led
shines on the exterior reader to signal that the room is occupied. The
power relays of the switchboard and of the air-condition stay active
as long as the valid card remains into the reader, and also for 20 sec
after its removal. If the window or the balcony door of the room opens
for more than 10 sec, then the air-conditioning relay is de-activated.
The restarting of the air-conditioning is done after a minimum of 2,5
min, provided that the balcony door is closed again. This delay is
inserted to protect the air-conditioning compressor from frequent
restarts. Removing and inserting again the valid smart card into the
internal reader, the “do not disturb” led of the external reader
is activated, to inform the service personnel.
Technical
specifications: The system has the following interconnections: Inputs:
Outputs:
|
|
| Smart Card Access control |